On this page
Quick answer. If your air conditioner stops heating on a cold, damp day, the indoor fan goes quiet and the outdoor unit gives off what looks like steam, it is almost certainly defrosting. Frost on the outdoor coil blocks the airflow, so the unit pauses heating and melts it off. Mitsubishi Electric UK says this is usually cleared within a couple of minutes; Hitachi gives about 10 minutes as the normal maximum. Leave it running and it will go back to heating by itself.
This guide draws on what Mitsubishi Electric, Hitachi and Daikin publish for owners, read on 22 November 2026. Two of the pages are written for Australia and New Zealand; the mechanism is the same in a UK winter, but timings vary by model, so your manual has the final word.
What defrost mode is
In heating mode, a reversible air conditioner (an air-to-air heat pump) takes heat from the outdoor air and releases it indoors. The outdoor coil runs colder than the air around it. When that air is damp, its moisture freezes on the coil.
Daikin UK puts it simply: winter humidity is usually high, and when moist air flows through the outdoor unit and meets the cold metal, the moisture can freeze on it. Ice restricts the airflow through the coil, which cuts efficiency. Mitsubishi Electric Australia and Hitachi add that in extreme cases a heavy build-up can damage the outdoor unit.
So the unit melts it. Daikin says its heat pumps detect ice and defrost automatically, reversing the flow of refrigerant so that heat goes to the outdoor coil instead of the room. You do not need to do anything, and Daikin says there is no need to call an installer for a normal defrost.
How to tell your unit is defrosting
| What you notice | Indoors | Outdoors |
|---|---|---|
| Heating stops | Warm air stops; the indoor fan stops | The outdoor fan stops |
| Display | Many models show a defrost or standby light or message, or a blinking run light | The compressor keeps running |
| Noise | Usually quiet | A short hiss or rush of air as the cycle starts |
| "Steam" | None | A plume of vapour in cold, damp weather |
| Water | None | Meltwater dripping from the base of the unit |
Mitsubishi Electric UK describes the start of a defrost as a sound like air being released, "much quieter but similar to brakes on a lorry", often followed by a plume of steam. It says neither should cause alarm. The indoor and outdoor fan behaviour comes from Mitsubishi Electric Australia and Hitachi, who describe the same pattern.
How long it lasts and how often it happens
How long. Mitsubishi Electric UK says the frost is usually cleared within a couple of minutes. Hitachi says a cycle ends either when the outdoor coil sensor reads warm enough or, at the latest, after about 10 minutes. Mitsubishi Electric Australia gives the same rough 10 minute figure and says it can run a little longer if the last defrost did not clear all the ice.
How often. Units have built-in timers. Hitachi says a unit generally runs for at least about 35 minutes after starting before its first defrost, and then defrosts no more often than about every 35 minutes. Mitsubishi Electric Australia gives around 40 minutes. Mitsubishi Electric UK, writing about its Ecodan heat pumps, says that when the temperature hovers around freezing in humid air, a unit may defrost several times an hour.
When. Hitachi and Mitsubishi Electric Australia say defrosting begins when the outdoor coil gets to around 0°C or below. Mitsubishi Electric UK adds that frost can form when the outdoor air is still in low single figures, because the coil is colder than the air.
Why a damp 2°C day can be worse than a hard frost
The amount of moisture in the air matters as much as the temperature. Mitsubishi Electric UK notes that as the temperature keeps dropping the air tends to be drier, so a unit may defrost less often in a hard frost than on a raw, damp day just above freezing. That pattern fits much of a southern English winter.
Defrost or warm-up?
Not every pause is a defrost. When you first switch on in heating mode, Daikin says its units run a warm-up first so they do not blow cold air. The fan starts after one to four minutes, and the warm-up takes longer when it is cold outside. A pause at switch-on is warm-up. A pause after the unit has been heating for a while, with the outdoor fan stopped, is defrost.
What you should and should not do
Do:
- Leave the unit on. Mitsubishi Electric Australia and Hitachi both say not to stop it before the defrost ends, because restarting soon afterwards lowers efficiency and can damage the unit.
- Keep the outdoor unit clear of leaves, plants and anything stacked against it.
- Clean the indoor filters as your manual says.
- Make sure meltwater can drain away. Mitsubishi Electric Australia recommends raising an outdoor unit at least 100 mm off the ground so it is not sitting in a pool of cold, moist air.
- Ease the load. Both manufacturers say a lower set temperature, closed doors and drawn curtains mean the unit works less hard and defrosts less often.
Do not:
- Try to remove the ice yourself. The unit is built to melt it, and Daikin says a normal defrost needs no action from you.
- Switch off and on repeatedly to "reset" it, for the restart reason above.
When frequent defrosting points to a problem
Defrosting is normal. These signs are not:
- It has never heated well since it was fitted. Mitsubishi Electric Australia and Hitachi both say that if a unit has struggled from the first cold snap, it may be operated incorrectly or be too small for the room, and that correct sizing is the installing company's responsibility. Check the room with our the size calculator.
- The problem is new. Both say a recent change can mean a fault or maintenance is due. Clean the filters and clear the outdoor unit first, then call your installer.
- Ice stays on the coil after a cycle, or builds into a solid block.
- The unit shows an error code or the operation lamp blinks and the unit stops. Daikin's FAQ on a blinking operation lamp says to check that the air inlets and outlets of both units are not blocked.
- Water is pooling or freezing where people walk, which suggests the drain route needs sorting.
A yearly service is the simplest prevention. Of the 1,252 installers we list across southern England, 1,067 (85%) say they service air conditioning, 780 say they do repairs and 263 offer an emergency call-out, according to their own websites (checked October and November 2026). Find one near you in the servicing lists for Kent, Hampshire, London or Devon, or, for a fault that cannot wait, the Kent emergency repair list. Our air conditioning servicing guide explains what a service should include.
Does defrosting make heating with air conditioning expensive?
It costs something, because for a few minutes the unit moves heat to the outdoor coil instead of the room. Against that, a coil clogged with ice would work far less efficiently, which is why the manufacturers build defrost in. Ask your installer how the model's published seasonal efficiency (SCOP) was measured if you want to compare units for cold, damp sites. Our guide to heating with air conditioning works through the cost per kWh of heat against gas and electric heaters, and the running cost estimator lets you try your own numbers.
Some installers we list sell their systems for winter heat as well as summer cooling. SAFEXE in Exmouth says many customers use them as their main heating in the room in spring and autumn. Smith EcoFlow in Bromley explains that the same sealed refrigerant circuit runs one way in summer and the other way in winter. BlackRock Electrical in Oxford says a split system heats a room for roughly a third of the cost of direct electric heating; that is the installer's own claim. If you are choosing a system with winter in mind, read our guide to air-to-air heat pumps first.
Questions
Why has my air conditioner stopped blowing warm air in winter?
How long does air conditioner defrost mode last?
Is steam from my outdoor unit normal?
Should I turn off my air conditioner when it is defrosting?
Why does my air conditioner defrost more near freezing than in a hard frost?
Why does my air conditioner take a few minutes to blow air on heat mode?
Sources
- Mitsubishi Electric UK, What happens to a heat pump in the cold (explaining the defrost cycle) (read 22 Nov 2026)
- Mitsubishi Electric Australia, Air conditioning defrost cycle (read 22 Nov 2026)
- Hitachi Cooling & Heating New Zealand, Understanding the defrost cycle (read 22 Nov 2026)
- Daikin UK, Is it normal that my airco freezes? (read 22 Nov 2026)
- Daikin UK FAQ, The air conditioner does not blow air immediately after it starts operation in the heating mode (read 22 Nov 2026)
Written and checked by Alex Christou. Found a mistake? Tell us; our corrections policy explains what happens next.