A PIV unit is a small fan, usually in the loft, that pushes filtered air into the house so damp air leaves through the gaps. It helps most in leaky, humid homes and does little in dry ones. The best independent field test we found, 16 homes measured by BRE in 2000, saw the house-average change in relative humidity run from a 5.5% fall to a 1.4% rise. Below: unit, fitting and running costs with the workings, six questions for any fitter, and who states PIV in Brighton and Hove.
Quick answer: A PIV unit (positive input ventilation) is a loft fan that pressurises the house slightly. Standard units cost about £280 to £350 before fitting; heater models cost more. Running cost is bracketed at about £4 to £39 a year by Nuaire's own minimum and maximum wattage. It can reduce condensation in a leaky, humid home. It will not cure a cold home or a leak.
Last checked 26 October 2026: retailer prices, price guides, the Ofgem rate, Approved Document F, the Nuaire data sheet, Property Care Association guidance, the BRE article and the installer pages named below. Not checked: noise data sheets.
What a PIV unit is and how positive input ventilation works
Positive input ventilation is a fan that supplies filtered air to the middle of a house, usually through a diffuser in the hall or landing ceiling. That raises the air pressure slightly, so stale, moist air is pushed out through leakage paths and any extract fans. The Property Care Association (PCA), a trade body, describes the system this way in its October 2024 best practice guidance.
The air path
The unit sits in the loft and draws air from there. A duct carries it down to the diffuser. From the landing the air spreads through the house and leaves wherever it can: gaps around windows and doors, floor and ceiling leakage, trickle vents, kitchen and bathroom extractors.
A PIV unit has no outlet of its own, so it relies on the house leaking.
Why the unit sits in the loft
Loft air is usually a little warmer than outside air. The BRE article puts it at generally 2 to 3 C warmer, and the PCA cites about 3 C across a heating season. That takes the edge off the incoming air. It is not heating.
"Heat recovery mode" is not MVHR
Some units carry a "heat recovery" label. Nuaire's Drimaster-Eco data sheet explains it: an internal temperature sensor watches the loft and boosts the air volume when the loft is above a set temperature. That is loft warmth being used, with no heat exchanger anywhere. Real heat recovery ventilation works differently, and our guide to what MVHR is explains how.
Loft, wall and flat PIV unit types
Most PIV units are one of three kinds.
Loft units
The standard type. The fan sits on the loft floor or hangs from the rafters, and a short duct runs to the ceiling diffuser. Nuaire sells the Drimaster-Eco in two forms: a "loft control" version and a "hall control" version where the controls sit in the diffuser. The hall control version costs more, as the table below shows. Nuaire's data sheet gives the unit weight as 3.5 kg and the warranty as 7 years for the hall control model.
Units with a heater
Some models add an electric heater to warm the incoming air. The PCA says these are typically rated at 300 to 500 W and that their running cost should be considered. Retailers list heater versions of the Manrose, Envirovent and Vent-Axia units at £308.95 to £333.50 against £280.81 to £293.95 for the matching plain units.
Wall and flat units
Where there is no loft, a wall-mounted unit draws air through an outside wall and ducts it to a central diffuser. The PCA covers this type, including a fire damper where the duct passes through a hallway wall in a flat. The performance evidence is thinner: the BRE study measured loft units in houses, so nothing in this guide shows how well a wall unit works in a flat. If your home is a flat, our guide to air conditioning in flats covers the other constraints that apply to flats.
What a PIV unit costs: unit, fitting and running
Three numbers matter: the unit, the fitting, and what the fan costs to run. The first two are retail and price-guide figures. The third is our own arithmetic, with the method shown.
Unit price
Unit-only prices for standard loft models cluster at about £280 to £350 including VAT. Heater and extra-control models run from about £309 to £785. Prices move, and some retailers show struck-through "was" prices, so treat these as a snapshot.
| Unit | Retailer | Price inc VAT (read 26 Oct 2026) |
|---|---|---|
| Vent-Axia Lo-Carbon PureAir Home | Air Conditioning Centre | £280.81 |
| Manrose Lo-Watt Pivotal MANPIV | Air Conditioning Centre | £282.71 |
| Envirovent LoftVent LV2-EVL | Air Conditioning Centre | £293.95 |
| Nuaire Drimaster-Eco loft control | Air Conditioning Centre | £295.28 |
| Nuaire Drimaster-Eco loft control | Home Ventilation Solutions | £295 |
| Nuaire Drimaster-Eco hall control | Home Ventilation Solutions | £335 |
| Nuaire Drimaster-Eco hall control | Air Conditioning Centre | £349.28 |
| Manrose with 500 W heater (MANPIVH) | Air Conditioning Centre | £308.95 |
| Vent-Axia PureAir Home with heater | Air Conditioning Centre | £333.50 |
| Nuaire Drimaster-Eco Heat hall control | Air Conditioning Centre | £579.10 |
| Nuaire Drimaster Eco Nox Heat | Home Ventilation Solutions | £785 |
The same Nuaire Drimaster hall control model is £335 at one retailer and £349.28 at another. Check two or three before you buy.
Fitting
Price guides give ranges. Book a Builder UK puts a fitted job at £700 to £1,600 in total, with labour at £250 to £600 and electrics at £150 to £300, and adds 10% to 25% for London and the South East. Homebuilding & Renovating gives £700 to £1,000 on average. The one local installer figure we found is from Ernest Air Cooling in Shoreham, whose ventilation page gives a typical installed PIV cost of £850 to £1,500.
These are typical ranges, not quotes. Get at least two itemised quotes, and ask what the figure includes: the unit, the diffuser, ducting, the electrical connection, and sealing of loft hatch and ceiling gaps.
Running cost, with the workings
The Ofgem price cap for 1 October to 31 December 2026 is 26.32p per kWh for electricity on a standard variable tariff paid by Direct Debit, with a standing charge of 54.83p a day. Ofgem says the figure excludes VAT from 1 October 2026 to 31 March 2027. The cap is an average and varies by region and tariff. We leave the standing charge out because it is paid whether or not the fan runs. Our guide to air conditioning running costs uses the same method.
Nuaire's data sheet for the Drimaster-Eco hall control gives a power draw of 1.6 W minimum and 17 W maximum. A real unit sits between the two, depending on the airflow setting and the loft temperature. The arithmetic for a fan running every hour of the year (8,760 hours):
| Case | Workings | Energy | Cost a year at 26.32p |
|---|---|---|---|
| Nuaire minimum, 1.6 W | 0.0016 kW x 8,760 h | 14.0 kWh | about £3.69 |
| Retailer-listed loft control model, 15.3 W | 0.0153 kW x 8,760 h | 134.0 kWh | about £35 |
| Nuaire maximum, 17 W | 0.017 kW x 8,760 h | 148.9 kWh | about £39 |
So the range is roughly £4 to £39 a year, which is about 10.7p a day at the top. The 15.3 W figure comes from a retailer's listing, not the Nuaire data sheet.
A heater changes the sum. At 500 W, a heater costs 13.2p for each hour it runs (0.5 kWh x 26.32p). A cold spell with 100 hours of heating adds about £13. Left on all year it would come to about £1,153, which is why it should not be.
BRE's 2000 article adds a warning about savings. Its authors wrote that a low-energy PIV system will not directly save any energy. Against a conventional extract system giving the same ventilation, they put the best-case saving at about 150 W, or about 550 kWh over a heating season, and said real savings would be less. Do not buy one to cut a heating bill.
Does positive input ventilation stop condensation?
The evidence is mixed. Positive input ventilation can reduce humidity in a leaky, humid home, and the best independent measurement we found shows an effect that varies from house to house. We found no source that says it cures condensation.
What the field evidence says
The BRE study is by Roger Stephen of BRE's Centre for Building Performance Assessment and John Bradley of Home Ventilation, published in Building Services in April 2000. Note two things first. It is 26 years old, and Bradley worked for Home Ventilation, a Nuaire subsidiary, so one author's employer made PIV units. We read it in a copy held by the Air Infiltration and Ventilation Centre (AIVC).
In an unoccupied three-bedroom test house, the fan reduced relative humidity by around 7 to 10% even with internal doors closed. In 16 occupied homes in Merthyr Tydfil and Aldershot, the picture was less tidy:
- House-average relative humidity ranged from a 5.5% fall to a 1.4% rise.
- The fan worked in the most humid houses and had little effect in drier ones.
- The effect varied between rooms in the same house.
- Claims of relief from respiratory illness could not be substantiated.
The authors called the measured humidity performance "somewhat disappointing", and said occupants were more enthusiastic than the results suggested. Some householders were reluctant to let the fan be switched off for the study.
One more finding is practical. In the test house, tracer gas showed the real ventilation rate was about half what the fan airflow suggested, and the pressure rise was only about 2 Pa. The authors stress sealing gaps around pipes, cables and loft hatches in the upstairs ceiling, so the air the fan pushes in does not just leak back to the loft.
The 2023 case study
A 2023 paper by P. Lopez-Arce in the Journal of Building Survey, Appraisal & Valuation looked at one UK dwelling. We read the abstract only, because the full text is paywalled. It reports that PIV with an enhancement extract fan reduced atmospheric moisture and helped avoid surface condensation in the monitored home. It also says performance depends on location, installation, operation and maintenance, that published data are limited, and that more monitoring is needed.
One dwelling is a case study, not a trial. It fits the BRE result: PIV can work, and installation decides whether it does.
Why a PIV unit can fail to stop condensation
You may read that PIV cures condensation. The sources above support a narrower claim, and they point to five ways it fails:
- The moisture source is still there. Drying laundry indoors, cooking without an extractor and a leaking pipe all keep adding water.
- The home is cold. Condensation forms on cold surfaces. The PCA warns that over-ventilating a cold home can make condensation worse.
- The house is airtight. With no leakage path, the air has nowhere to go. The PCA says trickle vents are normally only needed with PIV in highly airtight homes, so in a tight house keep them open.
- The loft ceiling leaks. Part of the fan's air returns to the loft, as the BRE authors warn.
- The problem is structural damp or a single room. A whole-house fan will not fix rising damp or a leaking roof.
Approved Document F adds a related caution. Its paragraph 3.15 says that after window replacement, if ventilation is not provided by MVHR, increased airtightness may reduce beneficial ventilation. Sealing a leaky house without adding ventilation can raise condensation risk.
PIV pros and cons
In its favour. It is cheap to buy against MVHR and cheap to run. It filters the air it brings in, and the PCA says filters should usually last five years, though some may be less. It lowered humidity in the most humid BRE houses, and it needs no ductwork to every room.
Against it.
- The evidence is thin and old. The best field data is from 2000 and covers 16 homes.
- It relies on leakage. It does not suit a very airtight house, and the PCA guidance covers existing homes, not new builds.
- It brings in outside air without recovering heat, so a cold loft means cooler air arriving on the landing.
- It will not save energy, per the BRE authors.
- It is not a named method in Approved Document F, which can complicate sign-off (see below).
- Do not treat it as a radon fix on your own judgement. The PCA says ground gas control should be designed by a specialist.
Noise, cold draughts and why not to switch it off
Cold air on the landing is the usual complaint. BRE puts loft air at only 2 to 3 C warmer than outside, so in winter the incoming air is cold. A heater option exists for this reason, at the running cost shown above.
Noise depends on the model and on where the diffuser sits relative to bedrooms. We found no manufacturer decibel figure for the Drimaster-Eco, and a retailer's sound figure for a Vent-Axia model was not confirmed on a data sheet, so we publish none. Ask for the data sheet.
Do not switch the unit off in cold weather. The BRE authors report that in the test house and one field house, when the fan was switched off in cold weather, moist air rose up through the unit, condensed on the cold flexible duct and dripped from the diffuser. Switching off to avoid overheating in a hot loft is different; they note units typically do that at about 25 C. Leave it running.
PIV unit vs MVHR: the short version
Pick PIV when the home is leaky, has a loft, and the problem is moisture. Pick MVHR when the home is airtight, or when you want heat recovered and are prepared to pay for it. Our guides to MVHR cost and MVHR vs PIV go through the numbers.
The two work in opposite ways. PIV relies on air leaving through leakage and background vents. Approved Document F 2021 paragraph 1.72 says background ventilators should not be installed with MVHR, to avoid unintended air pathways. MVHR must also be commissioned: paragraph 4.1 requires a commissioning notice to go to building control.
Commissioning is not a formality. An NHBC Foundation and BRE study of 10 homes at Greenwatt Way in Slough found that nine MVHR fan units were recommissioned after about a year. PIV is simpler to install, but as the BRE data show, it proves less.
Do you need building control approval for a PIV unit?
Check before you buy. Approved Document F, the official guidance on meeting the ventilation requirements of the Building Regulations in England, lists three system types in Table 1.6: natural ventilation, continuous mechanical extract, and MVHR. Neither the 2021 edition nor the 2026 edition contains the words "positive input" (text search, 26 October 2026).
The document allows other solutions if it can be shown to the building control body that they meet requirement F1(1). The PCA, in section 3.6 of its guidance, says it is highly recommended that approval from the local building control body is obtained before work starts. This is general information for England only.
The PCA also sets a limit on any enhancement extract fan: continuous extract must not exceed 40% of the PIV's normal airflow. It also covers safety checks for open flues, asbestos in textured ceilings and fire dampers. Those belong to the installer's survey, and the PCA guidance is written for surveyors, not homeowners.
Who fits PIV in Brighton and Hove
PIV is not an F gas job, so the F gas registers we use for air conditioning installers do not apply here.
What we found
Of the firms we list, one states on its own website that it fits PIV (checked 26 October 2026). Cen Air Solutions, based in Worthing, says on its about page that it delivers MVHR and PIV ventilation solutions, and its Brighton and Hove page lists MVHR and PIV ventilation systems. Its home page says it has worked with heat recovery ventilation for more than 20 years. That is the firm's own claim. It publishes no PIV prices, brands or models. See the Cen Air Solutions listing for what else we found.
Ernest Air Cooling in Shoreham installs MVHR. Its ventilation page compares PIV with other systems, gives a typical installed PIV cost of £850 to £1,500 and says PIV units can be fitted in half a day. Confirm the unit and price in a written quote. The same page calls PIV a "condensation cure", which the evidence above does not support. Other ventilation firms on the site state MVHR or general ventilation, not PIV, in the pages we saved. We found no PCA membership data and no building control records.
On our MVHR installers page you can see which Brighton and Hove firms state MVHR or PIV, and where we found nothing. We list; we do not recommend, and we take no money to list or rank anyone.
Six questions to ask any fitter
- Will you survey the house first, including loft ceiling leakage, flues and any textured ceilings?
- Which model, and can I see its data sheet, including power draw and sound data?
- Is the quote itemised: unit, diffuser, ducting, electrics, sealing, making good?
- How will you deal with building control, given that PIV is not named in Approved Document F?
- Is an enhancement extract fan needed, and does it stay inside the 40% limit?
- What is the warranty term in writing, and when should the filter be changed?
Get at least two quotes, and run your own electricity numbers using the method above.
Questions
What is a PIV air system?
Do PIV units actually work?
How does an Envirovent work?
What is positive pressure ventilation?
What is the best air ventilation system for a home in the UK?
How much does a PIV unit cost to run?
Sources
- Property Care Association, Best Practice Guidance Document: PIV Systems, October 2024 (read 26 Oct 2026)
- Stephen and Bradley, Positive input ventilation, Building Services, April 2000, AIVC copy (read 26 Oct 2026)
- Nuaire, DRI-ECO-HC data sheet, hosted by Permagard (read 26 Oct 2026)
- Ofgem, Changes to the energy price cap between 1 October and 31 December 2026 (read 26 Oct 2026)
- HM Government, Approved Document F Volume 1, 2021 edition (read 26 Oct 2026)
- HM Government, Approved Document F Volume 1, 2026 edition (read 26 Oct 2026)
- Lopez-Arce, Can positive input ventilation tackle surface condensation and mould growth?, 2023, abstract only (read 26 Oct 2026)
- NHBC Foundation, Assessment of MVHR systems and air quality in zero carbon homes, August 2013 (read 26 Oct 2026)
- Air Conditioning Centre, PIV units, retailer prices (read 26 Oct 2026)
- Home Ventilation Solutions, PIV unit prices (read 26 Oct 2026)
- Book a Builder UK, positive input ventilation guide with cost breakdown (read 26 Oct 2026)
- Homebuilding & Renovating, Positive Input Ventilation explained (read 26 Oct 2026)
- Ernest Air Cooling, ventilation services page (read 26 Oct 2026)
- Cen Air Solutions, about page (read 26 Oct 2026)
- Cen Air Solutions, Brighton and Hove page (read 26 Oct 2026)
Written and checked by Alex Christou. Found a mistake? Tell us; our corrections policy explains what happens next.